ARG80175

Human IgG4 ELISA Kit

Human IgG4 ELISA 试剂盒 for ELISA and Human

Immune System kit

内含物

货号 内含物名称 包装 温度
ARG80175-001 Antibody-coated microplate 8 X 12 strips 4°C. Unused strips should be sealed tightly in the air-tight pouch.
ARG80175-002 Standard (Lyophilized) 3 X 0.7 μg/vial 4°C
ARG80175-003 Standard diluent buffer 40 ml 4°C
ARG80175-004 Antibody conjugate concentrate 400 µl 4°C
ARG80175-005 Antibody diluent buffer 16 ml 4°C
ARG80175-008 20X Wash buffer 50 ml 4°C
ARG80175-009 TMB substrate 12ml 4°C (Protect from light)
ARG80175-010 STOP solution 12ml 4°C
ARG80175-011 Plate sealer 4 strips Room temperature

概述

产品描述 ARG80175 Human IgG4 ELISA Kit is an Enzyme Immunoassay kit for the quantification of Human IgG4 in Serum, Plasma, Cell culture supernatants.
反应物种 Hu
应用 ELISA
特异性 No significant cross-reactivity or interference with Human IgG1, IgG2, IgG3
靶点名称 IgG4
偶联标记 HRP
偶联标记说明 Substrate: TMB and read at 450 nm
灵敏度 8 ng/ml
样品类型 Serum, Plasma, Cell culture supernatants
标准范围 15.6 - 1000 ng/ml
样本量 100 µl
精确 CV: less than10%
別名 Immunoglobulin G4

应用说明

检测时间 4 hours

属性

形式 96 well
存放说明 Store the kit at 2-8°C. Keep microplate wells sealed in a dry bag with desiccants. Do not expose test reagents to heat, sun or strong light during storage and usage. Please refer to the product user manual for detail temperatures of the components.
注意事项 For laboratory research only, not for drug, diagnostic or other use.

生物信息

背景介绍 IgG4 is present in very low levels in children younger than 10 years of age, so IgG4 deficiencies are not usually diagnosed before age 10. IgG4 may be undetectable in the serum of many “normal” adult individuals, and therefore low IgG4 alone is insufficient evidence of an antibody deficiency disorder requiring Ig replacement. IgG4–related systemic disease (IgG4-RSD), also known as hyper-IgG4 disease and IgG4-related disease is a disease in which inflammatory cells cause fibrosis, the deposition of connective tissue, in one or more organs. The disease is so named because the antibody subtype IgG4 can be detected on tissue samples and often at elevated levels in the bloodstream. The association with IgG4 is a relatively recent finding, and the condition has been described under numerous other names in the past. Diseases such asautoimmune pancreatitis, retroperitoneal fibrosis, mediastinal fibrosis, Riedel's thyroiditis, Mikulicz's syndrome, Kuttner's tumor and inflammatory pseudotumor are now regarded as forms of IgG4-RSD.
产品亮点 Related products:
IgG4 ELISA Kits;
New ELISA data calculation tool:
Simplify the ELISA analysis by GainData
研究领域 Immune System kit

检测图片 (1) Click the Picture to Zoom In

  • ARG80175 Human IgG4 ELISA Kit standard curve image

    ARG80175 Human IgG4 ELISA Kit results of a typical standard run with optical density reading at 450 nm.

Title Download Link
ARG80175 Human IgG4 ELISA Kit User's manual download icon Download