ARG81553

Human CD150 / SLAM ELISA Kit

Human CD150 / SLAM ELISA 试剂盒 for ELISA and Human

内含物

货号 内含物名称 包装 温度
ARG81553-001 Antibody-coated microplate 8 X 12 strips 4°C. Unused strips should be sealed tightly in the air-tight pouch.
ARG81553-002 Standard 2 X 10 ng/vial 4°C
ARG81553-003 Standard/Sample diluent 30 ml (Ready to use) 4°C
ARG81553-004 Antibody conjugate concentrate (100X) 1 vial (100 µl) 4°C
ARG81553-005 Antibody diluent buffer 12 ml (Ready to use) 4°C
ARG81553-006 HRP-Streptavidin concentrate (100X) 1 vial (100 µl) 4°C
ARG81553-007 HRP-Streptavidin diluent buffer 12 ml (Ready to use) 4°C
ARG81553-008 25X Wash buffer 20 ml 4°C
ARG81553-009 TMB substrate 10 ml (Ready to use) 4°C (Protect from light)
ARG81553-010 STOP solution 10 ml (Ready to use) 4°C
ARG81553-011 Plate sealer 4 strips Room temperature

概述

产品描述 ARG81553 Human CD150 / SLAM ELISA Kit is an Enzyme Immunoassay kit for the quantification of Human CD150 / SLAM in serum, plasma (heparin, EDTA) and cell culture supernatants.
反应物种 Hu
应用 ELISA
特异性 There is no detectable cross-reactivity with other relevant proteins.
靶点名称 CD150 / SLAM
偶联标记 HRP
偶联标记说明 Substrate: TMB and read at 450 nm.
灵敏度 78 pg/ml
样品类型 Serum, plasma (heparin, EDTA) and cell culture supernatants.
标准范围 156 - 10000 pg/ml
样本量 100 µl
精确 Intra-Assay CV: 4.9%
Inter-Assay CV: 5.5%
別名 Signaling lymphocytic activation molecule; IPO-3; CD150; SLAM; CDw150; CD antigen CD150

应用说明

检测时间 ~ 5 hours

属性

形式 96 well
存放说明 Store the kit at 2-8°C. Keep microplate wells sealed in a dry bag with desiccants. Do not expose test reagents to heat, sun or strong light during storage and usage. Please refer to the product user manual for detail temperatures of the components.
注意事项 For laboratory research only, not for drug, diagnostic or other use.

生物信息

数据库连接

GeneID: 6504 Human SLAMF1

Swiss-port # Q13291 Human Signaling lymphocytic activation molecule

基因名称 SLAMF1
全名 signaling lymphocytic activation molecule family member 1
生物功能 High-affinity self-ligand important in bidirectional T-cell to B-cell stimulation. SLAM-induced signal-transduction events in T-lymphocytes are different from those in B-cells. Two modes of SLAM signaling are likely to exist: one in which the inhibitor SH2D1A acts as a negative regulator and another in which protein-tyrosine phosphatase 2C (PTPN11)-dependent signal transduction operates. [UniProt]
产品亮点 Related products:
CD150 antibodies; CD150 ELISA Kits;
New ELISA data calculation tool:
Simplify the ELISA analysis by GainData
翻译后修饰 Phosphorylated on tyrosine residues by FYN. [UniProt]

检测图片 (1) Click the Picture to Zoom In

  • ARG81553 Human CD150 / SLAM ELISA Kit standard curve image

    ARG81553 Human CD150 / SLAM ELISA Kit results of a typical standard run with optical density reading at 450 nm.

Title Download Link
ARG81553 Human CD150 / SLAM ELISA Kit User's manual download icon Download